The data submittal requirements shown in this section are required pursuant to section 1695 of this Article.
(a) All appliances.
(1) The data submittal requirements shown in Table A-1 are required for all appliances subject to this Article.
|
Required Information |
Possible Answers |
|
* Manufacturer’s Name |
|
|
* Brand Name |
|
|
| |
|
Manufacture Date |
|
|
Is a connected device or connected ready device |
Connected Device, Connected Ready Device, Neither |
* Identifier information as described in section 1695(a)(2)(l) of this Article
(2) The data submittal requirements shown in Table A-2 are required for any appliance that is a connected device, as defined in section 1691 of this Article.
|
Required Information |
Possible Answers |
|
Unit has a unique logical identification accessible to authorized entities |
True, False |
|
Only authorized entities are allowed to change the software configuration |
True, False |
|
Unit has data protection for personal information |
True, False |
|
Unit requires a user to generate a new means of authentication before access is granted to the device for the first time |
True, False |
|
Device supports plain text passwords |
True, False |
|
Plain text passwords, if supported, can be six characters or longer |
True, false, not applicable |
|
Plain text passwords, if supported, can include a combination of alpha, numeric, and special characters |
True, false, not applicable |
|
Unit allows authorized entities to check for software updates from the manufacturer, and to receive and apply available updates |
True, False |
|
Manufacturer provides security update policy and end of security support date |
True, False |
|
At restart, unit automatically restores recently saved settings |
True, False |
|
At restart, unit automatically restores recently saved network connection |
True, False |
|
Unit automatically attempts to reconnect after loss of connection |
True, False |
|
Unit allows the local users to override the schedule and/or delay timer |
True, False |
|
The unit allows authorized entities to change its settings |
True, False |
|
Unit allows the user to restore default settings |
True, False |
(b) Pool controls.
The data submittal requirements shown in Table B-1 are required for pool controls.
|
Required Information |
Possible Answers |
|
Unit communicates using open standards |
True, False |
|
Local control provides for start and stop of pool filter pump and dependent booster pumps and heaters |
True, False |
|
Integrated or separate user interface is provided for setup, selection, and update of the operating schedule |
True, False |
|
Unit retains memory for at least 72 hours without external power |
True, False |
|
System clock has ability to sync with local time automatically |
True, False |
|
The pool control is preprogrammed with a default operating schedule setting |
True, False |
|
Default operation of pool filter pump at ≥50% of max rpm starting no earlier than 9 a.m. and ending by 3 p.m. local time |
True, False |
|
Default operation of pressure cleaner booster pump starting no earlier than 9 a.m. and ending by 3 p.m. local time |
True, False |
|
Default operation of electric pool heater starting no earlier than 9 a.m. and ending by 3 p.m. local time |
True, False |
|
No default operation between 4 p.m. and 9 p.m. local time |
True, False |
|
Unit is marked with its manufacturer's name, its brand name, or its trademark; its model number; and its date of manufacture |
True, False |
Credits
Note: Authority cited: Sections 25213, 25218, 25402(f) and 25402.11, Public Resources Code. Reference: Sections 25216.5(d), 25402(f) and 25402.11, Public Resources Code.
History
1. New section filed 2-20-2024; operative 4-1-2024 (Register 2024, No. 8.
This database is current through 12/27/24 Register 2024, No. 52.
Cal. Admin. Code tit. 20, § 1696, 20 CA ADC § 1696